<b>°Ë»ö »ó¼¼º¸±â : [SPE]</b> - Extrahera¢â, SLE & SPE ÀÚµ¿È­ ½Ã½ºÅÛ
Notice

ÆǸŰ³½Ã!
TurboVap® LV • II • EH
All New & All Better!.

new TurboVap µÑ·¯º¸±â

• Gas Vortex Shearing Technology
• End-Point °¨Áö ¼¾¼­
• Multi Rack: ¿©·¯ Å©±â Tube ¼ö¿ë
• °¡½º ¸Å´ÏÆúµå Á¶Àý ±³Ã¼ °¡´É
• ´Ù¾çÇÑ Á¾·á¸ðµå: Manual Time Endpoint Endpoint+Time Method

• 7" Ä÷¯ ÅÍÄ¡½ºÅ©¸° Á¦¾îÆÇ ³»Àå
• 4¸éÀÌ Åõ¸íÇÑ À¯¸® ¼öÁ¶
• Àü¸é ¹è¼ö Æ÷Æ®
• ¼öÁ¶ Á¶¸í°ú °æº¸À½À¸·Î Á¾·á ¾Ë¸²
• ÀýÀü¸ðµå¿Í ÀÚµ¿ ¿þÀÌÅ©¾÷

     
 
Home > Product > SPE > Biotage > Instruments

Á¦ Ç° ¸í : Extrahera¢â, SLE & SPE ÀÚµ¿È­ ½Ã½ºÅÛ
Á¦ Á¶ »ç : Biotage
Á¦Ç°ÄÚµå : 414001
°ü·ÃÀÚ·á: pps353_extrahera_brochure.pdf (4,709,371 KB)
 
   
»ó¼¼¼³¸í

Extrahera¢â

SLE & SPE Automation System
Plate & Column, ¸ðµÎ¸¦ ó¸®ÇÏ´Â °­·ÂÇÑ »ç¿ëÀÚ Ä£È­Àû ÀÚµ¿È­ ½Ã½ºÅÛ!
No! Áö·çÇÑ ¼öµ¿ ÃßÃâ ÀÛ¾÷.

Extrahera¢â


¡î SLE & SPE °íÁ¤¹Ð ÀÚµ¿È­
¡î 12" ¸ð´ÏÅÍ Á¦¾îÀåÄ¡ ³»Àå
¡î Áøº¸ÇÑ Method °³¹ß ±â´É & ³ôÀº ÀçÇö¼º
¡î ÄÄÆÑÆ®ÇÑ µðÀÚÀÎ
¡î Positive PressureÀÇ Á¤¹ÐÇÑ Flow Á¦¾î
¡î 96-well Plate, 96 columns(1mL), 24 columns(1, 3, 6 mL) ó¸®
¡î Pipette TipÀÇ °¢ Sample & Solventº° Àç»ç¿ë
¡î °£°áÇÑ »ç¿ëÀÚ Interface : Method ÀúÀå/Àç»ç¿ë & pdf º¸°í¼­ »ý¼º
Ordering Information
Part Number Description Qty
414001 Biotage¢ç Extrahera¢â 1
414007 Configuration Kit 96 Positions 1
414008 Configuration Kit 24 Positions 1
     
121-5202 Collection plate, 96-well, 1 mL (50/pk) 1
121-5203 Collection plate, 96-well2 mL (50/pk) 1
414257SP Collection Rack 18 mm 24 Positions 1
     
414253SP Column Rack 96 x 1 mL (tabless) 1
414169SP Column Rack 24 x 1 mL 1
414174SP Column Rack 24 x 3 mL 1
413640SP Column Rack 24 x 6 mL (tabless)  
     
414254SP Sample Rack 16 x 100 mm 24 Positions 1
414255SP Sample Rack 13 x 100 mm 24 Positions 1
414256SP Sample Rack 12 x 75 mm 24 Positions 1
     
414201SP Flow Through Plate 96  
414203SP Flow Through Plate 24  
     
414141 Biotage Disposable Tips 1000 ¥ìL Clear (10 x Pk/96) 1
356330 Vacuum pump ME1C, 100-230 VAC, 50-60H 1
 
 
Technical Specs
Pipetting Specifications Up to 1000 µL in one aliquot
At 50 µL: ¡¾2.0% accuracy and 1.0% CV*
At 100 µL: ¡¾2.0% accuracy and 1.0% CV*
At 500 µL: ¡¾1.5% accuracy and 1.0% CV*
At 1000 µL: ¡¾1.0% accuracy and 1.0% CV*
Solvent Capacity 5 solvent pumps with automatic feed in from external reservoirs
Pressure Unit 0–5 bar positive pressure
Format 96-well extraction plates, 96-array plates for 1 and 2 mL wells
96-position extraction racks for 1 mL tabless columns (A format)
24-position extraction racks for 1, 3 and 6 mL columns (A, B and C format)
Plate Positions 5 positions used for sample, extraction and mixing plates etc. 4 used for elutions
Disposable Tips 1000 µL tips
Temperature Operating temperature: 15–32 ¨¬C
Storage and transportation temperature -25 ¨¬C to 60 ¨¬C
Humidity 10–95% RH
Electrical Supply 100 to 240 V~, 50/60 Hz
Fuses T4A at the power inlet (2 required)
Maximum Power Consumed 300 VA
Pressurized Air Supply >5 L/min (0.18 cubic feet/min), 6 ¡¾ 0.2 bar (0.6 ¡¾ 0.02 MPa; 87 ¡¾ 3 psi)
Inert Gas Supply >5 L/min (0.18 cubic feet/min), 6 to 10 bar (0.6 to 1.0 MPa; 87 to 145 psi)
Vacuum Supply Partial pressure range: < 500 mbar (50kPa; 7 psi)
Flow rate: > 8.3 L/min (0.29 cubic feet/min)
Weight 75 kg (165 lbs)
Dimensions (W x D x H) Without touch screen: 610 x 510 x 730 mm (24.0" x 22.1" x 28.7")
With touch screen: 860 x 570 x 730 mm (33.8" x 22.4" x 28.7")
Max Sound Level 65 dB (A)
Touch Screen 12" Capacitive Touch
Ethernet LAN Complies with IEEE 802.3 (ANSI 8802-3)
USB USB 2.0
Certifications CE, CSA certified
*Values derived using a 1000 µL tip.